Permit: T05PL02010

Parcel: 129132530


Addresses:

808 E 33RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/27/2005 PLUMBING - FINAL Approved IVRS - Inspection :*WATER HTR. VENT CONNECTION OK
LEAVING GAS CARD.
12/21/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALL SECTIONS OF SINGLE WALL VENT SHALL BE SECURED W/SCREWS THE TRANSITION OF SINGLE WALL TO DOUBLE WALL SHALL BE SECURED W/SCREWS - TAPE IS NOT ALLOWED AT THIS TRANSITION -- DOUBLE WALL VENT REQUIRES A 1" CLEARANCE FROM COMBUSTIBLE MATERIAL.
12/20/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER VENT SHALL BE SECURED WITH SHEET METAL SCREWS
2) PROVIDE CORRECT VENT CAP
3) REMOVE TAPE AT TRANSITION FROM SINGLE WALL VENT CONNECTOR TO DBL WALL VENT. SECURE WITH SCREWS
4) CORRECT WATER HEATER VENT AND RECALL FINAL INSPECTION
12/19/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*GAGE READING 0
FIND & CORRECT LEAK, PROVIDE PRESSURE TEST.
12/15/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*PREVIOUS CORRECTIONS HAVE NOT BEEN MADE. GAS LINE DETAILS 8" 10"
WATER HEATER NOT PROPERLY VENTED
T & P NOT TERMINATED
BONDING?