Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) 8.6 PSI 11;42 AM-11:52 AM PRESSURE TEST OK 2) PIPING IN GROUND OK TO COVER |
|
| 12/19/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/15/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/12/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* POST ADDRESS PSI 4.3 PSI - 7.5 MIN PSI REQUIRED ON TEST YARD PIPING REQUIRED TO HAVE A MIN OF 12" OF COVER WH SHALL BE PROTECTED BY A WEATHERPROOF ENCLOSURE WH REQUIRES MIN 5' VENT - DOUBLE WALL WHERE EXPOSED GAS PIPING SHALL BE BONDED T+P MUST TERMINATE VERTICALLY 6-24" ABOVE GRADE T+P DRIPPING |