Permit: T05PL02010

Parcel: 129132530


Addresses:

808 E 33RD ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/20/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1) 8.6 PSI 11;42 AM-11:52 AM PRESSURE TEST OK
2) PIPING IN GROUND OK TO COVER
12/19/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/15/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/12/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
POST ADDRESS
PSI 4.3 PSI - 7.5 MIN PSI REQUIRED ON TEST
YARD PIPING REQUIRED TO HAVE A MIN OF 12" OF COVER
WH SHALL BE PROTECTED BY A WEATHERPROOF ENCLOSURE
WH REQUIRES MIN 5' VENT - DOUBLE WALL WHERE EXPOSED
GAS PIPING SHALL BE BONDED
T+P MUST TERMINATE VERTICALLY 6-24" ABOVE GRADE
T+P DRIPPING