Permit: T05PL01994

Parcel: 136370980


Addresses:

4182 S EVERGREEN AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/23/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12 PSI TEST FROM METER UNDERGROUND TO OVERHEAD TO WATER HEATER, FURNACE ONLY - OK
GAS CARD @ METER 889-1888
12/22/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
READ NOTES FORM 12/20/05 INSPECTION
REMOVE TAPE FROM SINGLE TO DOUBLE WALL VENT CONNECTION AT WATER HEATER, PROVIDE 3 GALV SCREWS AT EACH JOINT OF JOINT PIPING. FOR WATER HEATER & FURNACE
12/20/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE SCOTCH COATED PIPE, PRIMED & TAPED FITTING ON ALL UNDERGROUND PIPING OR PRE-FABRICATED APPROVED RISER FOR P.E. TUBING
2. PLASTIC PIPING REQUIRES 18" MINIMUM COVERAGE FOR UNDERGROUND INSTALLATION
3. NO ACCESS INTO BUILDING HAVE AN ADULT PRESENT TO PROVIDE ACCESS -- THIS IS NOT A COMPLETE LIST