Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*NO TEST ON SYSTEM. NOBODY HOME WHEN SCHEDULING THIS INSPECTION THROUGH THE IVR SYSTEM-LEAVE A MESSAGE. RE INSPECTED 12:00 PM CORRECTIONS MADE OK OK FOR GAS CARD LEFT AT METER |
|
| 12/06/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* SHALL PROVIDE A ROOF FLASHING @ ALL ROOF PENETRATIONS AND SEALED SHALL PROVIDE AGA OR CSA GAS SHUT OFF VALVES @ ALL APPLIANCES SHALL EXTEND WALL FURNACE FLU VENT AND TERMINATE 2'-0" ABOVE COOLER. SHALL EXTEND T & P DRAIN TO DAYLIGHT TEMINATE WITH A 90 DEGREE 6" ABOVE SUB GRADE. SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT @ WATER HTR FLU VENT AND APPLIANCE COLLAR. RE TEST THE SYSTEM 10 LBS MIN. |