Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05PL01966

Parcel: 136121790


Addresses:

9652 E STELLA RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/08/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
12/06/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE BONDING OF BUILDING GAS PIPING
2. PROVIDE AGA OR CSA APPROVED GAS VALVE AT WATER HEATER
3. PROVIDE 3 GALV SCREWS AT CONNECTIONS OF ALL VENT PIPING OF APPLIANCES.
4. PROVIDE AGA OR CSA APPROVED GAS VALVE AT FURNACES
5. PROVIDE APPROVED COUPLING AT FLEX CONNECTION TO FURNACE.
6. WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING TO GRAVITY DRAIN TO DAYLIGHT OR HAVE CITY SIGNED PETITION OR APPROVAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF ON SITE WITH CORRECT INSTALLATION