Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 11 PSI TEST FROM METER UNDERGROUND TO STOVE, WATER HEATER, FURNACE & DRYER OK -- GAS CARD @ METER 889-1888 |
|
| 12/12/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE APPROVED COUPLING UNDERGROUND WITH PRIMER & THEN 10 MIL TAPE AT JOINT & TOOL MARKS 2. PROVIDE LEFT-RIGHT NIPPLE & COUPLINGS WHERE UNIONS ARE NECESSARY 3. WATER HEATER T&P DRAIN TO GRAVITY DRAIN TO DAYLIGHT 4. WATER HEATER REQUIRES MINIMUM 100 SQ.IN. LOWER COMBUSTION AIR OPENING. 5. PROVIDE AGA OR CSA VALVES AT SERVICE ENTRY & AT ALL APPLIANCES. 6. SEAL OFF FURNACE RETURN AIR OPENING IN FLOOR OR FURNACE CLOSET. 7. REMOVE TAPE FROM SINGLE TO DOUBLE WALL CONNECTION AT FURNACE VENTING IN CLOSET. 8. PROVIDE BONDING OF BUILDING GAS PIPING RETEST GAS SYSTEM |