Permit: T05PL01921


Addresses:

6126 E SPEEDWAY BL

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/15/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/10/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
12/02/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* SHALL PROVIDE THE REQUIRED TEST GAUGE FOR LOW PRESSURE GAS SYSTEM
SHALL EXTEND AND TERMINATE T & P DRAIN TO DAYLIGHT OR PROVIDE A FUNNEL DRAIN AND TERMINATE T & P DRAIN TO FLOOR DRAIN.
SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR FOR WATER HTR FLU VENT.
CHECK T & P VALVE FOR IT TO BE IN WORKING ORDER.
SHALL PROVIDE BONDING OF GAS LINE # 6 WIRE MIN.
RE TEST THE SYSTEM.
11/30/2005 PLUMBING - GAS PRESSURE TEST Cancelled
11/30/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*