Permit: T05PL01920

Parcel: 136344410


Addresses:

7451 E VICTORIA DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/12/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD AT METER 889-1888
12/02/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*NOT READY
11/30/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*10 PSI TEST SHALL HELD WITH NO PRESSURE LOSS FOR 15 MINUTES.
VENT FROM WATER HEATER TO HAVE 3 GALV SCREWS AT EACH JOINT AND BE INSTALLED CORRECTLY
PROVIDE BONDING OF BUILDING GAS PIPING
WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE RIDGID FULL SIZE PIPING GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.
PROVIDE AGA OR CSA APPROVED GAS VALVES AT APPLIANCES.
PROVIDE COUPLING AT ROOF TOP UNIT PIPING AND SUPPORT & SECURE GAS PIPING AT THAT LOCATION.