Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER 889-1888 |
|
| 12/02/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*NOT READY | |
| 11/30/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*10 PSI TEST SHALL HELD WITH NO PRESSURE LOSS FOR 15 MINUTES. VENT FROM WATER HEATER TO HAVE 3 GALV SCREWS AT EACH JOINT AND BE INSTALLED CORRECTLY PROVIDE BONDING OF BUILDING GAS PIPING WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE RIDGID FULL SIZE PIPING GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION. PROVIDE AGA OR CSA APPROVED GAS VALVES AT APPLIANCES. PROVIDE COUPLING AT ROOF TOP UNIT PIPING AND SUPPORT & SECURE GAS PIPING AT THAT LOCATION. |