Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05PL01913

Parcel: 131070340


Addresses:

6121 E 24TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/12/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD @ METER 889-1888
12/06/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*VENT FROM WATER HEATER TO TRAVEL 1/4"PER FOOT UPHILL TO POINT OF TERMINATION.
WATER HEATER TEMPERATURE PRESSURE RELIEF DRAIN TO GRAVITY DRAIN TO DYLIGHT( CANNOT TRAP WATER)
GAS FIRE PLACE TO HAVE FLUE VENT THAT IS UNABLE TO BE CLOSED TO PREVENT RISK TO LIVES.
THIS IS NOT VACANT HOUSE, AN ADULT WILL BE REQUIRED TO BE PRESENT AT FUTURE RE INSPECTION THIS IS NOT A COMPLETE LIST.