Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05PL01903

Parcel: 138132760


Addresses:

5908 S LIBERTY AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05PL01903

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/28/2005 PLUMBING - FINAL Approved IVRS - Inspection :*PRIMER AND WRAP BURIED GAS PIPING FOR PROTECTION FROM CORROSION.
INSTALL APPROVED AGA GAS VALVES AT APPLIANCES LOCATIONS. REMOVE GAS FLEX FROM FIRE BOX OF RANGE.
PROVIDE BONDING OF GAS LINE
REMOVE UNION FROM PIPING RUN, OR INSTALL VALVE AHEAD OF UNION.
PROVIDE 10 PSI MIN PRESSURE TEST ON SYSTEM