Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 12/09/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3 PSI ON 30 PSI GAGE ONE POUND INCREMENTS 1. GAGE REQUIRED TO HAVE 1/10 PSI INCREMENTS 2. BONDING OF GAS LINE. 3. FURNACE FLUE VENT MUST BE DOUBLE WALL ABOVE ROOF 4. SUPPORT OVERHEAD PIPING AT CHANGE OF DIRECTION. |
|
| 12/02/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :*SOMEONE MUST BE HOME TO PROVIDE ACCESS. RETURNED AT 2:30 AT REQUEST OF LARRY FROM TERRITORIAL. NOT READY. PROVIDE AGA VALVE AT WH. REMOVE TRAP FROM T & P DRAIN. CONNECT PIPING AT HOUSE. PROVIDE BONDING OF GASLINE PE GAS LINE NOT TO CORRECT DEPTH. CURRENTLY AT 11": REMOVE ROCKS & CALICH FROM DITCH PROVIDE TRACER WIRE FOR NON METALIC PIPING. RETEST 10 PSI. |