Permit: T05PL01886

Parcel: 120074990


Addresses:

225 W AVIATION DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/08/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
GAS PIPING TO WATER HEATER AND RANGE ONLY
PRESSURE TEST OK
CORRECTIONS HAVE BEEN MADE
OK GOR GAS - INSTALL PLUG OR RANGE
BEFORE CALLING SW GAS FOR SERVICE - SW GAS 889-1888
12/06/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*PRESSURE GAGE READING 0 PSI AIR TEST REQUIRED. IF LEAKING.CORRECT LEAKS.
12/01/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*PROVIDE APPROVED FLASHING FOR ROOF PENETRATION. T & P TO TERMINATE AB? 6"
PROVIDE APPROVED SINGLE WALL VENT OFFSETS
PROVIDE BONDING.
RETEST CALL FOR INSPECTION
11/30/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :CORRECTIONS FROM PREVIOUS LIST NOT COMPLETED
NOTE: SUPPORTS ON ROOF MUST BE WEATHER RESISTANT MATERIAL.
COUPLINGS ON PIPING MUST BE A LISTED FITTING. THREAD PROTECTORS ARE NOT LISTED COUPLING.
11/29/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*