Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05PL01864
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/30/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*13 PSI TEST IS OK LEFT GAS CARD. |
|
11/23/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*TEST SHALL HOLD 10 PSI WITH NO DROP FOR 15 MIN |
|
11/21/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*WHERE UNIONS ARE NECESSARY LEFT RIGHT NIPPLES & COUPLINGS SHALL BE USED PROVIDE GAS VALVE MAXIMUM OF 3' ON PIPING FROM APPLIANCE RIDGID PIPE OR PROVIDE BTU RATED FLEXES FOR ROOF TOP UNITS. |