Permit: T05PL01857

Parcel: 135022990

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/22/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/18/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*1) UNION AT SERVICE ENTRY SHALL HAVE AGA OR CSA APPROVED GAS VALVE PRECEEDING IT OR PROVIDE LEFT-RIGHT NIPPLE & COUPLING.
2) PROVIDE BONDING OF BUILDING GAS PIPING.
3) PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES
4) PROVIDE 3 GALV SCREWS AT EACH JOINT OF WATER HEATER & FURNACE FLUE VENT PIPING.
5) PROVIDE 100 SQ INCH LOWER COMBUSTION AIR FOR FURNACE.
6) SECURE GAS PIPING TO WATER HEATER.