Permit: T05PL01853

Parcel: 136310260

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05PL01853

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/06/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/29/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*SHALL SECURE PROPERLY THE 1/2" C.W SUPPLY TO WATER CLOSET IN MASTER BATH
SHALL PROVIDE 2- 10 X10 MIN LOUVER GRILLS FOR WATER HTR ENCLOSURE LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR
12/07/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*SEE MATERIAL TYPE FOR WATER PIPING INSTALLATION INSTRUCTIONS AND INSTALL ACCORDING TO THEM. SEE NOTES ABOVE FROM 11/28/05 INSPECTION ON TUB & SHOWER VALVES SUPPORT. PAY REFEE WITHIN 5 DAYS OR PERMIT WILL BE FROZEN. NO FINAL INSEPCTION SHALL BE DONE UNTIL REFEE IS PAID.
11/28/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* READ ALL NOTES, DO ALL NECESSARY WORK, PROVIDE ADDITION OF WATER HEATER TO PERMIT, SECURE SHOWER & TUB & SHOWER VALVES CORRECTLY, FINISH ALL THIS THEN CALL FOR INSPECTON OR FACE REFFE.
ZIP TIES ARE NOT CORRECT METHOD TO SECURE ANY PIPING
11/21/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE PERMIT FOR NEW WATER HEATER.
EXPOSE WATER PIPING ON INTERIOR WHERE NECESSARY FOR INSPECTION
PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS.
PROVIDE CORRECT VENT PIPNG FOR WATE HEATER TERMINATING 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE, WITH APPROVED VENT CAP.
SECURE WATER PIPNG AT ANGLE STOPS, AT CORRECT INTERVALS FOR MATERIAL USED AND WITH APPROVED METHODS FOR SUPPORTING & SECURING
11/17/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 2:30 NO ACCESS. PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS TO WATER SYSTEM AT TIME OF RE INSPECTION.