Permit: T05PL01839

Parcel: 135074470


Addresses:

1450 S EASTSIDE LP

Inspection Status: Approved

Inspection History: SITE - SEWER

Date Description Inspector Results Comments
10/31/2006 SITE - SEWER Approved IVRS - Inspection :*
08/23/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
- FROM MANHOLE #4 8" SDR 35 TO BUILDING AIR TEST OK
NO LOSS

1. SHALL SEE CONNECTION TO BUILDING.
2. SHALL WITNESS MANHOLE VACUUM TESTING.
3. SHALL RECEIVE AUTHORIZATION TO DISCHARGE FROM PCDEQ.
- FROM MANHOLE #3 8" SDR 35 TO MANHOLE #4 AIR TEST OK
NO LOSS
- FROM MANHOLE #2 8" SDR 35 TO MANHOLE #3 AIR TEST OK
NO LOSS
- FROM MANHOLE #1 8" SDR 35 TO MANHOLE #2 AIR TEST OK
NO LOSS
- FROM MANHOLE #1 8" DUCTILE TO EXISTING PUBLIC MANHOLE AIR TEST OK -- NO LOSS.
08/15/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
HOLD OVER TO 10:00 AM 8/15/06 PER TROY AT DIVERSIFIED REQUEST
08/14/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
08/04/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
8" STUB FROM MANHOLE #2 ONLY TOWARD #5
8" STUB FROM MANHOLE #3 TOWARD BUILDING 2 ONLY,
8" FROM MANHOLE #4 TO 5' FROM BUILDING 1
BEDDING, LAYING OK
1. PROVIDE CORRECT TRACER WITH SHAPING FOR BACKFILL.
08/02/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM MANHOLE #1 8" SDR TO MANHOLE #2
MANHOLE #2 TO #3
MANHOLE #3 TO #4
INCLUDING DUCTILE IRON AS SHOWN ON PLAN
BEDDING, LAYING, TRACER, SHADING OK
07/31/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
07/26/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
07/24/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
EXCAVATION ONLY FROM 5/1/06 INSPECTION NO CHANGE ON PIPING. REMOVE DEBRIS FROM PIPING AREA & PROVIDE GOOD SHADING MATERIAL.
05/01/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
8" DUCTILE IRON FOR EXISTING MANHOLE 2820-04 TO NEW MANHOLE #1 AND 8" SDR APP. 10' TOWARD MANHOLE #2 BEDDING, LAYING, SHADING, TRACER OK
1. WILL NEED AIR TEST ON PIPING, VACUUM TEST ON MANHOLES, VERIFICATION OF GRADE, ADEQ AUTHORIZATION TO DISCHARGE AT LATER DATE.
04/27/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
HAD PRE-CON WITH JOE ARIZONA EXCAVATING