Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T05PL01834
Inspection Description - SITE - SEWER
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2007 | SITE - SEWER | Approved | IVRS - Inspection :* | |
| 07/03/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* VACUUM TESTING TODAY REVIEWED PAPERWORK WITH CHRIS |
|
| 06/22/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* TESTING CONTINUES -- MANDREL TESTING TODAY RETEST TWO SECTIONS THAT FAILED PLEASE RECALL AGAIN FOR TOMORROW. |
|
| 06/21/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. LANDMARK ENGINEERING TESTING AND ENTERING TIMES ON FORMS FROM ADEQ WITH SELECT USA. |
|
| 06/20/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 06/16/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* PLEASE LEAVE A NAME AND NUMBER AND APPROX. TIME WHEN SCHEDULING INSPECTION. |
|
| 06/14/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* OK TO COVER TO C.O #3 THIS COMPLETES UNDERGROUND PIPING NOW STARTS TESTING |
|
| 06/09/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FROM M.H #11 TO M.H #12 INCLUDING CLEANOUT #17 |
|
| 06/08/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR 35 FROM M.H #9 TO M.H #10 OK 6" BRANCH PIPING TO C.O. #2 AND #15-16 OK TO COVER SUBJECT TO TEST AND GRADE. |
|
| 06/07/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. SDR 35 6" BRANCH FOR CLEAN OUTS #13 & #14 OK TO COVER SUBJECT TO TEST AND VERIFICATION OF GRADE. |
|
| 06/06/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR 35 FROM M.H #8 TO M.H #9 OK TO COVER SUBJ. TO TEST AND VERIFICATION OF GRADE. NEED TO SEE BRANCH PIPING FOR C.O #13 & #14. 2. MANHOLES (6) STACKED OK OK TO COVER. |
|
| 06/05/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FROM MANHOLE #7 TO MANHOLE #8 (TEN FEET PAST) OK TO COVER SUBJECT TO TEST AND VERIFICATION OF GRADE OK TO POUR SIX BASES. CHRIS CAN DOCUMENT CONCRETE. |
|
| 06/02/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. MH #2 TO MH#7 8" SDR 35 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST. |
|
| 06/01/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR 35 FROM MANHOLE #3 TO M.H #4 OK FROM M.H # TO C.O. #7 OK TO COVER. SUBJECT TO TEST AND VERIFICATION OF GRADE. |
|
| 05/31/2006 | SITE - SEWER | Partial Approval | 1. 8" SDR 35 STARTING AT 5+00 WITH 6" BRANCH CLEAN OUT #12 UP TO MANHOLE #3 OK TO COVER. SUBJECT TO TEST AND VERIFICATION OF GRADE. |
|
| 05/30/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. FROM CLEAN-OUT #11 THROUGH M.H. #2 INCLUDING CLEAN-OUT #06 UP TO CLEAN-OUT #12 OK TO COVER, SUBJECT TO TEST AND VERIFICATION OF GRADE |
|
| 05/25/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 2" SDR 35 FROM 2 TO0 TO 3 TOO INCLUDING CLEANOUT #10 CLEAN OUT #5 UP TO BUT NOT INCLUDING CLEANOUT #11. 2. METHOD OF GACKFILL IS TYPE 1 - NO COMPACTION REQUIRED ON NATIVE SOILS. |
|
| 05/23/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR 35 FROM EXISTING MH #1 TO NEW MANHOLE #1 OK TO COVER. 2. BRANCH PIPING FOR C.O #4 OK TO COVER. OK TO COVER UP TO 2 TO 0 |
|
| 05/19/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. DISCUSSED WITH TODD FROM PATHWAYS REQUIREMENTS FOR PRIVATE SEWER. 2. APPROVAL FOR CONSTRUCTION FROM D.E.Q 10/12/05 3. CONTRACTOR WILL REVIEW FLOW CHART. |
|
| 04/20/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 04/13/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* |