Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE |
|
| 11/14/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*REQUIRE 10# MINIMUM AIR TEST HARD PIPE IN FRONT OF FURNACE BLOCKS THE ACCESS DOOR T & P RELIEF DRAIN:MAY NOT TERMINATE IN A PAN-WHICH WON'T HOLD WATER MAY NOT HAVE THREADS AT THE TERMINUS CAP OFF ABANDONED PIPING WATER HEATER AND FURNACE MUST BE ABLE TO BE REMOVED WITHOUT AFFECTING GAS PIPING |
|
| 11/14/2005 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :*10 PSI TEST IS OK PROVIDE A BOND JUMPER TO GAS LINE PROVIDE A PETITION OF APPEAL & 125 PSI RELIEF VALVE IN WATER SUPPLY FOR ALTERNATE METHOD OF TERMINATING T & P PROVIDE MIN 3 SCREW IN ALL JOINTS OF VENT CONNECTORS. RECALL FOR INSPECTION |