Permit: T05PL01778

Parcel: 127051140


Addresses:

4817 E 2ND ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/15/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE
11/09/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*SHALL PROVIDE THE REQUIRED TEST GAGE FOR LOW PRESSURE GAS 10 LBS MIN TEST.
SHALL EXTEND THE WALL FURNACE FLU VENT AND TERMINATE 2'-0" ABOVE COOLER
SHALL SEAL GAS LINE PENTRATION FOR KITCHEN RANGE SUPPLY
SHALL PROVIDE BONDING GROUND ON GAS LINE
SHALL PROVIDE SCREWS PER JOINT VENT & COLLAR ( (3) SHEET METAL @ WATER HTR FLU