Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*GAS PRESSURE TEST IS OK ALL CORRECTIONS HAVE BEEN MADE NOTE: OWNER SAID HE WILL ATTACH THE BOND WIRE. MIN #6 WIRE FROM WATER SUPPLY TO GAS SUPPLY @ WATER HEATER. |
|
| 11/04/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*WATER HEATER EXPANSION TANK TO BE SUPPORTED WATER HEATER T & P DRAINS TO BE SEPARATED AND GRAVITY DRAIN TO DAYLIGHT WATER HEATER FLUE VENT TO HAVE 3 GALV SCREWS AT EACH JOINT AND BE MADE UP CORRECTLY WITH APPROVED MATERIALS PROVIDE ACCESS TO UPPER ROOF AND ALL UNITS PROVIDE ROOF FLASHING ON ALL PIPE PENETRATIONS PROVIDE WEATHER PROOF SUPPORTS FOR PIPING ON OFF WITH SECURING AT CORRECT INTERVALS. PRIME & TAPE ALL TOOL MARKS ON UNDERGROUND PIPING |