Permit: T05PL01721

Parcel: 122010540


Addresses:

1632 N LOUIS LN #03


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05PL01721

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE
10/26/2005 PLUMBING - GAS PRESSURE TEST Cancelled IVRS - RI canceled
10/26/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* ONLY A LICENSE PLBG CONTRACTOR CAN DO ANY WORK ON A GAS SYSTEM FOR RENTAL PROPERTY
SHALL USE THE REQUIRED TEST GAGE FOR PRESSURE TEST
SHALL PROVIDE DBL WALL FLU VENT THRU THE ROOF WITH CAP FOR WATER HTR THE YOU CAN USE SINGLE WALL VENT CONNECTOR AND PROVIDE (3) SHEET METAL SCREWS PER JOINT ON FLU VENT AND APPLIANCE COLLAR.
SHALLL HARD PIPIE THRU WATER HTR ENCLOSURE THEN CONNECT FLEX CONNECTOR.
SHALL EXTEND WALL FURNACE FLU VENT AND TERMINATE 2" ABOVE COOLER
SHALL SEAL GAS LINE PENETRATION THEN WALL
SHALL SEAL ROOF JACKS ON ROOF
SHALL BLOCK AND STRAP GAS LINE ON ROOF
PLEASE REMOVE DOOR FOR WATER HTR ENCLOSURE.