Permit: T05PL01717

Parcel: 123022320


Addresses:

2527 E LESTER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/07/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) PRESSURE TEST OK
2) CORRECTIONS MADE OK
3) OK FOR GAS
11/01/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE ACCESS INTO HOUSE AND ATTIC SPACE
YOUR PRESSURE GAUGE SHOULD READ IN 1/10LB INCREMENTS. WE ARE WATCHING FOR SMALL LEAKS, INCREASING PRESSURE TO 50 PSI IS NOT A SUBSTITUTE.
THANK YOU FOR REMOVING SILVER PAINT, WE NEED TO VERIFY LISTED PIPE. THERE ARE SOME LOCAL HOME CENTERS THAT SELL BLACK STEEL PIPE THAT DOES NOT MEET THE RIGOROUS STANDARDS WE REQUIRE IN THE USA
YOU MAY NOT USE A GROUND FACE UNION WHERE PIPE ENTERS APT BEHING WASHING MACHINE. PLEASE USE A LEFT/RIGHT NIPPLE.