Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) PRESSURE TEST OK 2) CORRECTIONS MADE OK 3) OK FOR GAS |
|
| 11/01/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE ACCESS INTO HOUSE AND ATTIC SPACE YOUR PRESSURE GAUGE SHOULD READ IN 1/10LB INCREMENTS. WE ARE WATCHING FOR SMALL LEAKS, INCREASING PRESSURE TO 50 PSI IS NOT A SUBSTITUTE. THANK YOU FOR REMOVING SILVER PAINT, WE NEED TO VERIFY LISTED PIPE. THERE ARE SOME LOCAL HOME CENTERS THAT SELL BLACK STEEL PIPE THAT DOES NOT MEET THE RIGOROUS STANDARDS WE REQUIRE IN THE USA YOU MAY NOT USE A GROUND FACE UNION WHERE PIPE ENTERS APT BEHING WASHING MACHINE. PLEASE USE A LEFT/RIGHT NIPPLE. |