Permit: T05PL01702

Parcel: 117092060


Addresses:

1116 S 4TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/08/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
10/25/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*WATER HEATER TEMPERATURES & PRESSURE RELIEF DRAW TO TERMINATE 6"-24" FROM FINISH GRADE.
PROVIDE DOUBLE WALL VENT PIPE FROM EXIT OF WEATHER PROOF ENCLOSURE TO APPROVED VENT CAP FOR WATER HEATER.
RIGID PIPE NIPPLE SHALL PENETRATE APPLICANCE HOUSING.
PROVIDE BONDING OF BUILDING GAS PIPING
SUPPORT GAS PIPING TO STOVE & WALL HEATER.
PROVIDE 3 GLAV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING. NOT READY.