Permit: T05PL01700

Parcel: 140232250


Addresses:

6034 S EUCLID AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/03/2005 PLUMBING - FINAL Approved IVRS - Inspection :*GAS PRESSURE TEST OK
ALL CORRECTIONS HAVE BEEN MADE
10/31/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*12 PSI TEST FROM METER UP OVERHEAD TO ROOF TOP UNIT, STOVE & WATER HEATER OK
SEE NOTES ON THIS PAGE ABOVE AND COMPLY NOT READY
10/27/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*NO ACCESS PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS AT TIME OF REINSPECTION.
GAS PIPING UNDERGROUND SHALL HAVE FITTINGS AND TOOL MARKS PRIMED THEN TAPED
WATER HEATER REQUIRES DRAFT HOOD
VENT FROM WATER HEATER REQUIRES 3-GLAV SCREW AT EACH JOINT AND 1" CLEARANCE FROM COMBUSTIBLES
PROVIDE APPROVED VENT CAP FOR WATER HEATER.
PROVIDE BONDING OF BUILDING GAS PIPING
THIS IS NOT A COMPLETE LIST.