Permit: T05PL01649

Parcel: 130121440


Addresses:

3746 E SHEPHERD PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/19/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
10/17/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS AT RE INSPECTION
10/14/2005 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE INSULATION ON EXTERIOR WATER PIPING AT CLAMP LOCATIONS
2) COMPLETE VENT PIPING FOR WATER HEATER
3) EXPOSE WATER PIPING AT METER AND AT SERVICE CONNECITON AT BLDG