Permit: T05PL01565

Parcel: 130180100


Addresses:

4158 E VALENTINE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/14/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) 11 PSI TEST FROM METER UNDERGROUND TO BLDG EXISTING SERVICE ENTRANCES TO WATER HEATER AND STOVE ONLY OK
2) GAS CARD AT METER
10/07/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*REQUIRE MINIMUN 10TH TEST
PAINTED PIPED UNDERGROUND NOT PERMITTED
ALL UNDERGROUND PIPING TO BE SCOTCHCOAT PIPING THAT IS MARRED BY WRENCHES AND FITTINGS SHALL BE COATED WITH TAPE PRIMER AND THEN SPIRALLY WRAPPED WITH 10 MIL TAPE.