Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* PETITION OF APPEAL #2005.253 OK SITE. CORRECTION MADE GAS CARD AT METER CALL S.W. GAS 889-1888 TO ENERGIZE GAS SYSTEM |
|
| 09/19/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CORRECT ELECTRICAL WIRING BLOCKING WATER HEATER PULL SPACE. PROVIDE RIGID PIPE NIPPLE THRU FURNACE APPLIANCE HOUSING 2) PROVIDE LISTED FLEX FOR BTU REQUIREMENT OF FURNACE 3) WATER HEATER REQUIRES TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION 4) SINGLE WALL VENT FROM WATER HEATER REQUIRES 6" MINIMUM CLEARANCE FROM COMBUSTABLES. DOUBLE WALL REQUIRES 1" CLEARANCE FROM COMBUSTABLES 5) GAS VENT APPLIANCES TERMINATE WITHIN 10' OF COOLER INTAKE REQUIRES VENT TERMINATION OF WATER HEATER TO BE 3' ABOVE, FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE 6) PROVIDE COMBUSTION AIR REQUIREMENTS FOR WATER HEATER |