Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER 889-1888 |
|
| 09/15/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/14/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VENT FROM WATER HEATER TO TRAVEL IN UPWARD DIRECTION 1/4" PER FOOT BE PIPED WITH APPROVED VENT MATERIAL AND FITTINGS TO POINT OF TERMINATION |
|
| 09/13/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE BONDING OF BLDG GAS PIPING 2) SECURE WATER HEATER DRAFT HOOD, MAKE UP VENT FROM WATER HEATER CORRECTLY, AND SECURE ALL JOINTS OF WATER HEATER VENT PIPING WITH 3-GALV SCREWS 3) WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING TO BE RIDGID (NO FLEX) GRAVITY DRAIN TO DAYLIGHT |