Permit: T05PL01427

Parcel: 132102540

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/28/2005 PLUMBING - FINAL Approved IVRS - Inspection :* GAS CARD AT METER. 18 PSI TEST FROM METER ON EXISTING PIPNG TO WATER HEATER FURNACE ONLY.
09/21/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SUPPORT FOR PIPING AT DRYER
2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT DBL WALL FURNACE VENT PER #2 9/16/05 INSPECTION
3) WATER HEATER VENT TO BE DBL WALL FROM EXIT OF WEATHER PROOF ENCLOSURE THRU ROOF, WITH CORRECT FLASHING AT ROOF AND APPROVED VENT CAP
4) RIDGID PIPE THRU WEATHER PROOF ENCLOSURE OF WATER HEATER, PROVIDE VALVE IN ACCESSIBLE LOCATION THEN FLEX TO WATER HEATER
5) PROVIDE BONDING OF BLDG GAS PIPING