Permit: T05PL01395

Parcel: 122183490


Addresses:

3553 E CAMDEN ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/06/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) ALL CORRECTIONS HAVE BEEN MADE
2) OK FOR DRYWALL
09/02/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHALL PROVIDE A 1 1/2" TRAP ARM MAX SIZE FOR LAVATORY
09/01/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CAN'T POSITION A COMBO IN A VERTICAL POSITION. THIS WILL PUT THE VENT OUTLET BELOW THE TRAP
2) SHALL PROVIDE 1 1/2" TRAP ARM ALL THE WAY TO THE BARREL USE A 4 X 1 1/2" SAN TEE
3) SHALL PROVIDE A L-SWEEP ON HORIZONTAL TO HORIZONTAL DRAINAGE AT TRAP ARM
4) SHALL REMOVE TEST TEE AND CONNECT SOLID. NO ABS THREADED FITTING CAN BE LOCATED IN A CONSEALED LOCATION. FLOW TEST OK
5) SHALL PROVIDE APPROVED SPECIALTY COUPLING WHEN CONNECTING DISSIMULAR MATERIAL