Permit: T05PL01388

Parcel: 123111690


Addresses:

1231 E LINDEN ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05PL01388

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/01/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
15 PSI TEST IS OK
LEFT GAS CARD
PROVIDE A 125 PSI RELIEF VALVE OUTSIDE ON WATER SUPPLY
PROVIDE A BOND JUMPER
WILL CHECK CORRECTIONS ON MECHANICAL INSPECTION
08/29/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE PERMITS FOR WATER HEATER AND ROOF TOP UNIT
2) PROVIDE CITY APPROVED GAS ISOMETRIC OF YOUR GAS SYSTEM AND HAVE INTERMEDIATE PLUMBING INSPECTION ADDDED ON A PERMIT FOR REWORK OF WATER HEATER PIPING AND EXPOSE THIS WORK
3) RINNAI WATER HEATRS REQUIRE CERTIFIED INSTALLERS PROVIDE CERTIFICATION ON SITE HEATER ALSO REQUIRES VENT THR ROOF AND COMBUSTION AIR INTAKE
4) ALL GAS APPLIANCES TO HAVE SHUT OFF VALVES WITHIN 3' OF APPLIANCE IN SAME SPACE
5) WATER HEATER T & P TO GRAVITY DRAIN TO DAY LIGHT
6) SECURE ALL GAS PIPING PROPERLY
7) WATER HEATER TO BE VALVED AND HAVE UNIONS ON INLETS