Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTION MADE 2) GAS CARD AT METER |
|
| 08/26/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VENT PIPING SHALL RISE AT 2 PERCENT MINIMUM PER NOTE #3 AND DBL WALL REQUIRES 1" MINIMUM CLEARANCE FROM COMBUSTIBLES, SINGLE WALL REQUIRES 6" MINIMUM CLEARANCE FROM COMBUSTIBLES AND BE SUPPORTED PROPERLY |
|
| 08/25/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SEE NOTE #4 AND PROVIDE 1" MINIMUM CLEARANCE FROM COMBUSTIBLES ON DBL WALL VENT PIPING |
|
| 08/23/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE UPPER COMBUSTION AIR 2) MAKE CORRECT CONNECTION FROM SINGLE WALL WYE FITTING TO DBL WALL PIPING 3) HORIZONTAL VENT PIPING TO RISE AT 2 PERCENT MINIMUM 4) PROVIDE PETITION OF APPEAL ON SITE FOR ALT. FORM OF T & P RELIEF WITH NIPPLE OUT OF 125 POUND PRESSURE RELIEF |
|
| 08/22/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |