Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK 2) SHALL SEE ON FINAL INSPECTION THE GAS PENETRATION INTO ATTIC SPACE SEALED AND A 90 DEGREE AT END OF T & P DRAIN |
|
| 08/18/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE FOR ALL APPLIANCES THERE AGA OR CSA APPROVED SHUT OFF VALVES AND FLEXES AND CAPP OFF THE END OF VALVE FOR KITCHEN RANGE 2) SHALL EXTEND T & P DRAIN TO DAYLIGHT AND CHECK T & P VALVE 3) SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT FOR WATER HTR FLU VENT CONNECTOR AND AT APPLIANCE COLLAR 4) SEAL GAS LINE PENETRATION 5) PROVIDE BONDING TO GAS LINE #6 WIRE MINIMUM |