Permit: T05PL01308

Parcel: 131120370


Addresses:

5950 E 30TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/18/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
08/17/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM 100 SQ INCH COMBUSTION AIR OPENINGS FOR BOTH UPPER AND LOWER COMBUSTION AIR TO FURNACE
2) VALVE SHALL BE BEFORE FLEX AT CONNECTION TO FURNACE
3) VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE
4) SECURE GAS PIPING IN ATTIC
5) SEAL GAS PIPING PENETRATIONS INTO BLDG-NOT READY