Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE NOTE #3 AS REQUESTED |
|
| 08/18/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK 2) ALL CORRECTIONS HAVE BEEN MADE |
|
| 08/12/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GAS GAUGE WAS AT 0 POUNDS-10 POUNDS MINIMUM REQUIRED 2) SHALL PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT ALL APPLIANCES 3) SHALL REMOVE FLEX LINE IN T & P DRAIN AND EXTEND IT TO DAYLIGHT 4) SHALL REMOVE MECHANICAL TAPE ON WATER HTR FLU VENT AND PROVIDE (3) SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR AND CENTER AND SECURE APPLIANCE COLLAR |