Permit: T05PL01299

Parcel: 124121070


Addresses:

1227 E MILES ST

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/18/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTE #3 AS REQUESTED
08/18/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) GAS PRESSURE TEST IS OK
2) ALL CORRECTIONS HAVE BEEN MADE
08/12/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS GAUGE WAS AT 0 POUNDS-10 POUNDS MINIMUM REQUIRED
2) SHALL PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT ALL APPLIANCES
3) SHALL REMOVE FLEX LINE IN T & P DRAIN AND EXTEND IT TO DAYLIGHT
4) SHALL REMOVE MECHANICAL TAPE ON WATER HTR FLU VENT AND PROVIDE (3) SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR AND CENTER AND SECURE APPLIANCE COLLAR