Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05PL01267
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTION MADE 2) GAS CARD AT METER |
|
| 08/09/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WATER HEATER T & P DRAIN TO BE FULL SIZE RIDGID PIPING. WATER HEATER VENT TO BE DBL WALL AT PENETRATION THRU ROOF WITH 1" MINIMUM CLEARANCE FROM COMBUSTIBLES AND HAVE AN APPROVED VENT CAP. (NORTH LOCATION) PROVIDE 3-GALVANIZED SCREWS AT EACH JOINT OF VENT CONNECTION 2) PROVIDE 3-GALVANIZED SCREWS AT EACH JOINT OF VENT FROM (SOUTH) WATER HEATER WITH APPROVED VENT CAP. SECURE GAS PIPE DROP AT (NORTH LOCATION) |