Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*GAS CARD AT METER | |
| 10/05/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*CLEAN PIPING AT BONDING CLAMP & ATTACH TO COLD WATER PIPING. SECURE GAS PIPING IN ATTIC & UP AT WALL TO ATTIC INSTALL WATER HEATER AND MAKE CONNECTIONS CORRECTLY PROVID E3-GLAV SCREWS AT EACH JOINT OF FLUE VENT PIPING |
|
| 09/07/2005 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) CLEAN LINT OFF OF LOW COMBUSTION AIR VENT 2) PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT ALL APPLIANCES 3) SECURE GAS PIPE IN CLOSET 4) PROVIDE PERMIT FOR WATER HEATER AND PROVIDE A PETITION FOR APPEAL FOR ALTERNATE METHOD OF TERMINATING T & P RELIEF DRAIN 5) REPLACE VENT CAP ON ROOF WITH APPROVED DBL WALL CAP 6) PROVIDE A BOND JUMPER ON GAS LINE 7) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS |