Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTION MADE PETITION OF APPEAL #2005.219 ON SITE FOR WATER HEATER T & P DRAIN |
|
| 07/27/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST SHALL HAVE MINIMUM 10 PSI AND HOLD FOR 15 MINUTES WITH NO PRESSURE DROP AT TIME OF INSPECTION 2) VENT FROM FURNACE TO TRAVEL IN UPWARD DIRECTION TO POINT OF TERMINATION 3) WATER HEATER T & P DRAIN TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY APPROVED PETITION OF APPEAL ON SITE FOR ALTERNATE FORM OF TEMPERATURE PRESSURE RELIEF FOR WATER HEATER 4) VENT FROM WATER HEATER TO BE 3' ABOVE, VENT FROM FURNACE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE 5) SECURE GAS PIPING IN FURNACE/WATER HEATER CLOSET |