Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*CORRECTIONS MADE OK PLUMBING FINAL OK |
|
| 09/07/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL ATMOSPHERIC VACCUM BREAKER ON HOSE BIB 2) REMOVE PLUG ON VERTICAL CLEANOUT UNDER SINK, AND INSTALL AIR ADMITTANCE VALVE 3) TRAP ARM AT LAVATORY STILL WON'T WORK. TRAP MAY ONLY BE ONE PIPE SIZE LARGER THAN THE TAIL PIECE TO WHICH IT IS CONNECTED |
|
| 08/23/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PVC RISER FOR HOSE BIB MUST BE PROTECTED 2) SEE NOTE #2 FROM 7/26/05 3) DWV PIPING NOT APPROVED 4) TRAP ARM MAY NOT CHANGE SIZE 5) TRAM ARM TO LONG 6) KITCHEN SINKD DRAIN NOT APPROVED |
|
| 07/26/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) YARD WATER LINE FROM METER TO BLDG SUPPLY IS OK 2) NOTE: ALL EXPOSED WATER LINES WILL REQUIRE INSULATION 3) THERE HAS BEEN SOME NEW WAST AND VENT RE-PIPE. THIS ACTIVITY WILL REQUIRE A PERMIT. ALSO ABS MATERIAL CANNOT BE EXPOSED. SHALL PROVIDE PROPER MATERIAL FOR DWV SYSTEM 4) OK TO BACKFILL TRENCH |