Permit: T05PL01174

Parcel: 116184240


Addresses:

314 N MELWOOD AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/22/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
07/19/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 10 PSI TEST SHALL BE IN PLACE ON ENTIRE GAS SYSTEM AT TIME OF REINSPECTION
2) PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES
3) WATER HEATER GAS VALVE TO BE IN REACHABLE LOCATION
4) PROVIDE BONDING OF BLDG GAS PIPING
5) PROVIDE 6" MINIMUM CLEARANCE FROM COMBUSTIBLES FOR SINGLE WALL VENT PIPING FROM WATER HEATER AND PROVIDE DBL WALL VENT PIPING THRU ROOF