Permit: T05PL01146

Parcel: 112071090


Addresses:

2729 E WATER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/15/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
07/12/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE 1'' CLEARANCE AROUND DBL WALL FLU VENT FROM COMBUSTIONABLE MATERIAL. 2) SHALL PROVIDE A 3" CONCRETE BASE FOR WATER HTR. 3) SHALL PROVIDE( 3) SHEET METAL SCREENS @ APPLIANCE COLLAR FOR WATER HTR FLU VENT. 4) SHALL CONNECT BONDING TO GAS LINE FROM ELECTRIC PANEL. 5) GAS PRESSURE TEST IS OK 6) SHALL SEAL GAS PENETRATION FOR RANGE.