Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/06/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CAST IRON OK. 1) SEE NOTE #1 7/5/05 INSPECTION. 2) REINSTALL ROUND CLAMP TO COLD H20 PIPING. 3) WATER HEATER ELECTRICAL FEEDERS ARE REQUIRED TO BE # 10 SIZE WIRE. 4) MAKE WEATHER PROOF ENCLOSURE WEATHER PROOF. | |
| 07/05/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) ALL EXTERIOR WATER PIPING TO BE INSULATED 2) ALL CAST IRON TO BE INSTALLED IN PRACTICAL ALIGNMENT, IN WORKMANSHIP LIKE MANNER AND WITH CORRECT PITCH 3) STRAPPING NOT PERMITTED ON FITTINGS. STRAPS TO BE APPROPRIATE SIZE AND CONNECTED IN AN APPROVED MANNER |