Permit: T05PL01084

Parcel: 123130450


Addresses:

938 E HAMPTON ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05PL01084

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
12/09/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/07/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE WEATHER RESISTANT SUPPORTS ON ROOF, SECURE WITH 2 HOLE STRAPS.
CORRECT VENT ON FURNACE - CANNOT CHANGE BACK TO SINGLE WALL AFTER INSTALLING DOUBLE WALL.
PLEASE CALL FOR RE-INSPECTION.
07/06/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :* 1) NO VENT ON FURNACE. 2) PENETRATIONS THROUGH THE ROOF REQUIRE APPROVED FLASHING. 3) ROOF TOP GAS TO BE SUPPORTED. 4) REMOVE TAPE BETWEEN VENT CONNECTOR AND VENT 5) REMOVE COMBUSTIBLES FROM NEXT TO VENT CONNECTOR 6) NO TEST.