Permit: T05PL01076

Parcel: 120022040


Addresses:

4401 S 16TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/29/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
06/28/2005 PLUMBING - FINAL Partial Approval IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK 3) OK TO BACKFILL TRENCH. 4) NOTE: SHALL PROVIDE (2) 10 X10 MIN. LOUVER GRILLS FOR WATER HTR ENCLOSURE LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR. SHALL PROVIDE A MIN OF 1" CLEARANCE AROUND DLB WALL FLU VENT @ WATER HTR AND PROVIDE (3) SHEET METAL SCREWS PER JOINT @ WATER HTR APPLIANCE COLLAR AND FLU VENT. 6) RE CALL FOR FINAL INSPECTION ONLY