Permit: T05PL01060

Parcel: 14024045B

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
07/11/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK
07/08/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) DOOR AND GATE IS LOCKED. 2) SHALL PROVIDE GRILL OR SCREEN @ TOP COMBUSTION RELIEF VENT. 3) SHALL CUT OFF THREADS @ END OF T & P DRAIN. 4) CLEAN FLOOR IN WATER HTR ENCLOSURE OF DEBRI.
06/24/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE A AIR PRESSURE TEST ON ENTIRE SYSTEM WITH A MINIMUM OF 10 LBS @ TIME OF INSPECTION. 2) SHALL CUT OFF THE THREADS @ THE END OF T & P DRAIN FOR WATER HTR. 3) SHALL PROVIDE (2) 10 X10 LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR @ WATER HTR DOOR.