Permit: T05PL01036

Parcel: 138180980

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
06/30/2005 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) HCS CONNECTION IS OK. 3) SEWER MAIN TAP IS OK. 4) SEPTIC TANK HAS BEEN PUMPED AND THE BOTTOM OF TANK HAS BEEN BROKEN. 5) OK TO BACKFILL TRENCH
06/24/2005 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :* 1) OBTAIN RIGHT OF WAY PERMIT FOR EXCAVATION IN ALLEY. 2. WHERE 4" AC WATER LINE IS CROSSING 4" ABS SEWER 2' MINIMUN IS REQUIRED DEPTH OF SEPARATION, BETWEEN PIPES OR USE OF DUC?? IRON PIPING IS REQUIRED ON SEWER. 3. PROVIDE PROOF OF HOLE IN BOTTOM OF SEPTIC TANK THAT IS DELETED.