Permit: T05PL01030

Parcel: 128121520


Addresses:

4709 E MONTECITO ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/23/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/21/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :* 1) WHERE UNIONS ARE NECESSARY LEFT RIGHT NIPPLES & COUPLINGS SHALL BE USED. 2) PROVIDE BONDING OF BUILDING GAS PIPING. 3) PROVIDE WEATHER PROOF ENCLOSURE FOR WATER HEATER. 4) VENT FROM FURNACE TO HAVE 3- SCREWS AT EACH JOINT AND BE EXTENDED 2" ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE.
06/17/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*