Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2005 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection :* 12 PSI AIR TEST FROM NEW METER LOCATION TO WATER HEATER DRYER, AND ROOF TOP UNIT ONLY. |
| 06/21/2005 |
PLUMBING - GAS PRESSURE TEST |
|
Not ready for Inspection |
IVRS - Inspection :* 1) TEST TO HOLD MINIMUM 10 PSI FOR 15 MINUTES. 2) PIPING IN ATTIC SPACE TO BE SUPPORTED PROPERLY AND CHANGES OF DIRECTION REQUIRES FITTINGS. 3) THREAD PROTECTORS ARE NOT COUPLINGS USE APPROVED COUPLINGS OR WHERE UNIONS ARE NECESSARY LEFT & RIGHT NIPPLES & COUPLINGS SHALL BE USED. 4) PROVIDE BONDING OF BUILDING GAS PIPING. |