Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05PL01011

Parcel: 129091660


Addresses:

1812 S CHERRY AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/21/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/15/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL RUN T & P DRAIN TO DAYLIGHT WITH PITCH OR OBTAIN AN APPEAL FORM FOR ALTERNATE METHOD OF T & P DRAIN. 2) SHALL PROVIDE ( 3) SHEET METAL SCREWS PER JOINT @ WATER HTR FLU VENT AND APPLIANCE COLLAR. 3) SHALL PROVIDE ROOF FLASHINGS FOR ALL GAS PENETRATIONS THRU ROOF. 4) SHALL PROVIDE APPROVED (2) HOLE STRAPS FOR 3/4" SUPPLY TO RANGE. 5) SHALL SEAL PENETRATION @ NORTH WALL.