Permit: T05PL00973

Parcel: 136384120

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/21/2005 PLUMBING - FINAL Approved IVRS - Inspection :* CORRECTION MADE GAS CARD AT METER
06/16/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 20 PSI AIR TEST FROM METER LOCATION EXISTING PIPING TO FURNACE & WATER HEATER ONLY APPROVED. 1) SEE NOTE # 4FROM 6/8/05 INSPECTION 2) PROVIDE BONDING OF BUILDING GAS PIPING
06/08/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE AN AIR PRESSURE TEST ON ENTIRE EXSISTING GAS SYSTEM WITH A MIN OF 10 LBS @ TIME OF INSPECTION. 2) SHALL REPLACE FURNACE GAS SHUT OFF VALVE WITH AN AGA OR CSA VALVE. 3) SHALL REMOVE FLEX LINE IN T & P DRAIN @ WATER HTR AND PROVIDE A FULL SIZE 3/4" DRAIN. 4) SHALL EXTEND WATER HTR FLU VENT MIN 3'-0 ABOVE COOLER AND FURNACE FLU VENT MIN 2'-0" ABOVE COOLER.